Troubleshooting Code 80041014 - Component failed to initialize
Introduction to Code 80041014
Error code, 80041014 occurs when you execute a VBScript connecting to WMI (Windows Management Instrumentation). It means that COM cannot locate a provider referenced in the schema. A wild guess,
crucial DLLs have been accidentally de-registered from your machine.
The Symptoms You Get
The script does not manipulate the WMI object as you had hoped, instead you get a Windows Script Host error message.
The Cause of Code 80041014
It means that COM cannot locate a provider referenced in the schema. In practical terms it means that the files used by WMI have been deleted or become corrupt.
The Solutions
You need to re-register all the .DLL and .EXE files needed for WMI.
From the CMD prompt, navigate to the %windir%\System32\Wbem directory. Type the following at the command prompt and then press ENTER:
for %i in (*.dll) do RegSvr32 �s %i
After the .DLLs have
been re-registered you will then need to re-register any .EXE files found in the Wbem folder, except for Mofcomp.exe and Wmic.exe. For example, to re-register the executable file Scrcons.exe type the
following from the command prompt:
regsvr32 �s scrcons.exe
‡
Example of Error Code 80041014 Script
No examples at present.
Seven
General Troubleshooting Strategies for 800 Errors
Windows Management Instrumentation (WMI) is one of the hidden
treasures of Microsoft operating systems. Fortunately, SolarWinds
have created the
WMI Monitor so that you can examine these gems of
performance information for free. Take the guess work out of which
WMI counters to use for applications like Microsoft Active Directory,
SQL or Exchange Server.
Thus utility makes it easy to check the health of a router or firewall. Check the real-time performance and availability statistics for any device
on your network.